Test report · CCR-001 Rev A · Oct 28, 2026

Component Characterization: 5-Pin Flick Switch

The TIMS control panel needed an octave switch, and the one I had was salvaged from a scrapped DVD/VCR player with no markings and no datasheet. Before designing around it, I measured which pins connect in each position, what the closed contacts add, and whether the open paths are isolated, against pass criteria set before testing.

Part
5-pin miniature flick switch, momentary, center-off. No part number or markings.
Source
Salvaged from the board of a scrapped DVD/VCR player (make and model unknown)
Use
TIMS Mk.1 control panel: octave down (left) and octave up (right) by default; reassignable in firmware
Test dates
Aug 30 and Sep 22, 2026 (initial checks); Oct 28, 2026 (full measurement)
Author
Anthony Rizvanov

Result: PASS, 6 of 6 criteria. Approved for the TIMS Mk.1 control panel.

Summary

The switch is a single-pole double-throw switch, momentary on both sides, with an off position at center, often written (ON)-OFF-(ON). Pins 2, 3 and 4 are one internal common. Pushing left connects pin 1 to it, pushing right connects pin 5, and pins 1 and 5 never connect to each other. The pin map was the same in all three test sessions, every closed path read within one meter count of the test-lead resistance, every open path read OL on the 2 MΩ range, and nothing changed after 100 actuations to each side.

Method

Pass criteria, set before testing

CriterionPass conditionResult
C1 · Switching mapSame pin pairs on every repeat; one consistent switch typePASS
C2 · Contact resistanceBelow 1 Ω on every closed pair; three readings within one meter countPASS
C3 · IsolationEvery open pair reads OL on the high resistance rangePASS
C4 · Body isolationBody isolated from every pin, or bonded to one documented pinPASS (plastic housing)
C5 · Return actionEach side returns to center on every release over 100 cyclesPASS
C6 · StabilityAfter 100 cycles per side, C2 still met; no new or missing connectionsPASS

Results

Continuity map

Readings in ohms on the 200 Ω range, including the 0.2 Ω test leads. “Open” means the meter read OL.

Pin pairA (left, held)Center (rest)B (right, held)
1–2Closed · 0.1OpenOpen
1–3Closed · 0.1OpenOpen
1–4Closed · 0.1OpenOpen
1–5OpenOpenOpen
2–3Closed · 0.1Closed · 0.1Closed · 0.1
2–4Closed · 0.1Closed · 0.1Closed · 0.1
2–5OpenOpenClosed · 0.1
3–4Closed · 0.2Closed · 0.2Closed · 0.2
3–5OpenOpenClosed · 0.2
4–5OpenOpenClosed · 0.1

Analysis

Every closed path read 0.1 or 0.2 Ω against a lead reading of 0.2 Ω, so the contacts add less than the meter’s 0.1 Ω resolution. Readings of 0.1 Ω, below the lead reading itself, show the results sit at the limit of what this meter can resolve; they are not exact values. Small toggle switches are generally specified in the milliohm range, which fits this result. Three of the five pins are one common, so any of them can serve as the common terminal.

Limitations: one sample; an uncalibrated meter whose accuracy specification wasn’t on hand; readings that include the soldered leads; and the metal pivot rivet and actuator tab weren’t checked against the pins.

Conclusion and Next Steps

The switch met all six criteria and is approved for the TIMS Mk.1 control panel.

Back to the TIMS documentation

More Engineering Work